AIR FLUX

The ARIA 19 Kit with a certified and properly installed filter, can assist in the filtration of breathable air and reduce the inhalation of contaminants.

APA adaptor has a non-return valve, so only fresh air passes through the filter and only filtered air enters into the mask.

The exhausted air has a different channel and it is expelled from the lower part of the mask, where another non-return valve ensures air will only exit from there.

(In the open source project is also available the design of  the Exhausted Valve Cover 22mm: an another adaptor made to filter the exhaled air).

Our snorkeling masks breathing technology is patented and certified.

The airflow and the CO2 levels are tested and safe.

The converted mask is a reusable and cleanable full-face shield.

CONFIGURATIONS

he adaptors allow to connect most common filters to the mask.

APA is compatible with all the filters with EN 148-1 connection.

RD40-22mm can be screwed on APA to connect HEPA filters (40mm 1/7″ threaded outlets).

All the Ocean Reef mask are compatible with our optical lens support.

Lenses are available in different graduation.

To filter exhausted air, wear a surgical mask on ARIA or install a filter with the exhaust valve cover (3D model available).

To filter exhausted air, wear a surgical mask on ARIA or install a filter with the exhaust valve cover (3D model available).

The adaptors allow to connect most common filters to the mask.

APA is compatible with all the filters with EN 148-1 connection.

RD40-22mm can be screwed on APA to connect HEPA filters (40mm 1/7″ threaded outlets).

All the Ocean Reef mask are compatible with our optical lens support.

Lenses are available in different graduation.

To filter exhausted air, wear a surgical mask on ARIA or install a filter with the exhaust valve cover (3D model available).

CERTIFICATION

On May 27 2020 Mestel Safety SRL-Ocean Reef Group received from the Italian National institute for insurance against industrial injuries, INAIL, the extraordinary validation (protocol: INAIL.72000.27/05/2020.0016170) for the Personal Protective Equipment of third category constituted by the Aria/UNO snorkeling mask assembled with the APA adaptor (Aria Protection Adaptor) and the P3 filter, certified under the EN136: 2000 standard. This validation complies with the Italian Law art.15 comma 3 decreto-legge Governo Italiano 17 marzo 2020, n.18 Emergenza COVID – 19.

DECONTAMINATION

After some preliminary tests carried out on Aria 19, APA and RD 40 adaptors, the following sanitization procedures are proposed.

They are based on recommendations from CDC, OSHA, the National Academy of Science and many hospitals in Europe, Canada, and USA. All the Aria 19 mask and adaptors are functional and seal well after each sanitization process.

 

  • Remove any filter connected to the adaptor prior to sanitization.
  • NEVER use any solvent, cleaner or abrasive product to clean the Aria 19 Mask, the RD40 and the APA Adaptor.
  • Do not sanitise a mask+adaptors protection system that is clearly damaged.
  • Be careful do not deform the Aria 19 Mask, the RD40 and the APA Adaptor during sanitization as it could negatively impact its fit.
  • Follow one of the methods below.Upon completion of the cycle, the filter, the Aria19 mask, the RD40 and APA adaptors must be stored in a closed PE bag ready for the next use in a dry and cool place. If one of them appears visually damaged or soiled, it should be discarded. Any mask and/or adaptors that has exceeded the sanitization cycles should be discarded as well.Please note that successful completion of the chosen method and cycle signifies appropriately sanitised filter, Aria 19 mask, RD40 and APA adaptors.

    Please note that this protocol is not formally approved, and each hospital should consult their EH&S officers or infection disease specialists for a standard operating procedure.